Skip to content

Lighting

LED drivers: choosing the rating, type and location

A guide to LED drivers: constant voltage and constant current, sizing with a safety margin, dimming, moisture protection, ventilation and a location that makes maintenance easy.

Arkan Almajara team · · 2 min read

Illustrative photo Lighting & Electrical Fit-Out

The short answer

A driver turns mains power into the low voltage a strip or downlight needs. Choose the right type (usually constant voltage for strips, constant current for some downlights), a rating about 20% above the load, compatibility with the dimming system, and a ventilated, reachable location.

  • Strips usually need constant-voltage drivers (12 or 24 V).
  • Rating = strip length × watts per metre, then add about 20% headroom.
  • Dimming needs a driver compatible with the dimmer or control system.
  • Drivers usually fail before strips, so put them where they can be replaced.

A strip lasts many years if it runs in the right conditions. The driver sets those conditions, and it is usually the first thing to fail.

Types

Type Use
Constant voltage (CV), 12 or 24 V LED strips and most profiles
Constant current (CC) Some downlights and modules whose maker specifies the current
Dimmable With a compatible dimmer or control system
Waterproof (high IP) Wet and outdoor locations

Sizing

  1. Load = strip length (m) × its power (W/m).
  2. Add about 20% headroom, so the driver runs cool and lasts.
  3. Choose the nearest available driver above the result, or split the load across several.

Example: 18 m of 10 W/m strip = 180 W. With headroom, 216 W: two 150 W drivers or three 100 W drivers depending on feed points. Work it out with the lighting calculator.

Dimming

Decide the system before buying: a wall dimmer, a smart control system, or protocols such as DALI or 0–10 V. The driver must be compatible, or flicker or buzzing follows.

Location

  • Ventilated, not buried in thermal insulation.
  • Reachable through an access panel or inside a unit.
  • Close to the strip, to keep low-voltage cable runs short.
  • Away from moisture, or with a suitable protection rating.

Records

Note in the handover file: where each driver is, its rating, and which circuit it feeds. This saves hours at maintenance time.

Read LED strip problems. The service: lighting.

Frequently asked questions

Can a driver go above a closed ceiling?

It can if there is a nearby access panel and enough ventilation. A buried driver with no access means opening the ceiling at the first fault.

One large driver or several small ones?

Several smaller drivers shorten feed runs and make a failure partial rather than total, but need more locations. We choose by the design and access points.

Share

Related service

Need this on your project?

Concealed light in ceilings and walls, recessed LED lines and spotlights on a grid — designed with the ceiling, not added to it.

Lounge with a gypsum ceiling, ring pendants and timber cladding