Fire-rated gypsum: what 60 minutes means and how it is achieved

How fire-rated gypsum board systems work in ceilings and partitions, why the rating belongs to the whole system rather than the board, and what civil defence checks.

Arkan Almajara team · · 2 min read

During works Steel stud partitions for the corridor and rooms, before boarding

The short answer

A fire rating (30, 60 or 120 minutes) is given to a tested system: board type and layers, frame, insulation, and how joints and openings are sealed. Pink board on an ordinary frame with open penetrations does not deliver the required rating.

  • The rating belongs to the whole system, built exactly as in its test certificate.
  • Openings and penetrations need fire-rated sealing materials.
  • Doors and access panels in a fire-rated wall must be rated too.
  • Where rated walls go is set by the civil defence drawings, not the contractor.

In hospitals, hotels and commercial buildings, some walls and ceilings are not decoration: they are barriers that give people time to get out. That time is what a figure such as 60 minutes means.

The rating belongs to the system

The whole system is tested in a standard furnace: board type and thickness, number of layers, studs and their spacing, insulation in the cavity, screw fixing and spacing, and joint treatment. The system receives a certificate for a set duration, and changing any one of these takes it outside the certificate.

A typical fire-rated partition

Part Role
Fire-rated boards Glass fibres hold the board together for longer
Usually two layers per face Delay heat reaching the frame
Rock wool in the cavity Slows heat transfer and improves acoustics
Staggered joints between layers No joint in one layer lines up with one in the next
Perimeter sealing Fire-rated sealant at ceiling, floor and walls

The weak points: openings

A fire-rated wall usually fails at a gap: a pipe, a cable, a duct, an electrical box or an access panel. Each needs a rated solution: collars and intumescent sealants, fire dampers in ducts, and rated doors and access panels.

What we do on commercial projects

  1. Read the civil defence drawings to find rated walls and ceilings and their duration.
  2. Choose a tested manufacturer system and attach its certificate and details.
  3. Build to the details: layers, spacing, insulation and joints.
  4. Coordinate with electrical and HVAC before boarding to deal with every penetration.
  5. Photograph each stage and hand over a file of the materials used.

On a project of partitions and ceilings for a private hospital, coordinating services before closing the walls took the most time, because that is what preserves the rating.

In short

Do not ask for “fire-rated gypsum”; ask for “a fire-rated system of so many minutes to such a certificate”. Read also drywall partitions vs blockwork and fire safety and finishes in commercial projects, and see our partitions and acoustics service.

Frequently asked questions

Is one layer of fire-rated board enough?

It depends on the system and the required duration. Some 30-minute systems use one board per face; 60 minutes usually needs two boards per face or a thicker board, per manufacturer.

Does a home need fire-rated gypsum?

Usually not in living spaces, but it is sometimes required around electrical rooms, garages or between units, depending on the local code.

Share

Related service

Need this on your project?

Interior walls on a steel frame with sound and thermal insulation — faster and lighter than blockwork, for offices, clinics and hotels.

Steel stud partitions for the corridor and rooms, before boarding
02

Drywall partitions and acoustics

Interior walls on a steel frame with sound and thermal insulation — faster and lighter than blockwork, for offices, clinics and hotels.

Details

Have a space or a drawing? Start with a site visit.

Tell us the type of space and its approximate size, and we will get back to you to book a time.